Product Details:
Payment & Shipping Terms:
|
Product Name: | Mini Pulse Oximeter | Screen: | Touch Screen |
---|---|---|---|
Routine Check Mode: | Routine Check Mode | Review: | Data Graph And Trend Table |
Operation: | Convenient | Storage: | More Than 10,000 Patient Cases |
High Light: | finger pulse oximeters,recording pulse oximeter |
Handheld Tabletop Pulse Oximeter With Spo2 Probe , Pulse Oximeter Machine Normal Readings
Model No : AH-60A
car used Vehicle handheld pulse oximeter
Rich Analysis Report
Perfect Mount Solution
Convenient operation by touch screen
Description:
Principle of the AH-50QA Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Integrated with SPO2 probe and processing display module.
Can be used in: hospital, home, community medical treatment, sport
Functions:
Routine Check Mode and Continuous Monitoring Mode
Data Graph and Trend Table Review
Rich Analysis Report
Perfect Mount Solution
Convenient operation by touch screen
Large SD card memory for more than 10,000 patient cases storage
Advanced analysys software for sleep study (Free with the oximeter)
Sync with PC based Sofrware (WinXP and WinVista)
Specification:
Performance Specifications:
Display: 3.5" Color TFT
Resolution: 320x240
Display Mode: Standard face, Waveform face, Display Direction adjustable
Indicator:Power indicator light, Alarm sound, Pluse tone
Interface:One dual-purpose socket for connecting SPO2 sensors and communication
Cables:
Power Supply:DC 5V, <200MA
Battery:Builtin Li-Polymer, 2 hours for charging, 8 hours for continous working.
Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
Trend Table:Resolution from 1s, 5s, 10s. Review up to 2000 items.
Alarm:Ajustable High and Low limits. Three level audible and vistual alarm
Technical specifications:
Safety
Meet the requirment of IEC60601 series
Type of Protection: Class II with internal electirc power supply
Degree of Protection:BF
Dimention and Weight
Dimention:92(W)x82(H)x22(D)mm
Weight:136g(with battery)
Operation Environment:
Temperature:0~ +40
Humidity:15% ~ 95%
Storage Environment:
Temperature:-20~ +60
Humidity:10% ~ 95%
Patient Range
Neonate ,Pediatric and Adult
SPO2:
Measurement Range:0 ~ 100%
Resolution:1%
Accuracy:±2%(70%~100%, Adult/Pediatric)±3%(70%~100%, Neonate)
0% ~ 69% unspecified
Alarm Range:0% ~ 100%
Refreshing Rate:1s
Pulse Rate:
Measurement Range:25 ~ 250 bpm
Resolution:1bpm
Accuracy:± bpm
Alarm Range:25 ~ 250 bmp
Refreshing Rate:1s